HomeProductsCAPILLARY SPINNER STAGE

CAPILLARY SPINNER STAGE

Bruker AXS
Part No:A52D57
Description
  • Capillary spinner stage for measurements of powders in capillary transmission geometry. The stage can optionally accommodate reflection sample holders (all 32 mm sample holders) or a dedicated flat film transmission holder.

    Specifications:

    • For capillaries from 0.1 to 1.8 mm diameter, minimum length 35 mm
    • Rotation speed can be adjusted between 0 rpm and 60 rpm
    • Magnetic base to hold either the included static goniometer head (for >0.5 to 1.8 mm diameter capillaries) or the optional compact goniometer head (for 0.1 to <=0.5 mm diameter capillaries)
    • Stage can be easily mounted by the user on the goniometer's self-centering stage-mounting interface.

    Included:

    • Alignment Kit (glass slit, fluorescent screen, corundum reference sample)
    • Primary side Guard-Slit Holder with 0.6mm plug-in slit to reduce scatter, and integrated beam stop.
    • Static goniometer head with two sets of capillary holders (0.6, 0.8, 1.1 mm)
    • Capillary Alignment Tool (CAT, A52D62) for gluing capillaries into capillary holders.
    • Two sets of capillary centering disks for CAT (A52D63), each consist of 9 pieces ranging from 0.5 to 1.6 mm
    • Static holder for 32mm diameter sample holders

    Required (not included):

    • Primary variable beam optics (A52D16)
    • Telescopic secondary optics (A52D51) extension, slit, axial Soller (A52D52, A52D53, or A52D55)

    Optional (not included):

    • Compact goniometer head (A52B47)
    • Extra static goniometer head (A52B115)
    • USB camera-microscope for capillary alignment (A52D64)
    • Set of 5 frames for foil transmission samples for capillary stage (A52D74)
    • Sets of 5 capillary holders: 0.3 mm (A52D66), 0.4 mm (A52D67), 0.6 mm (A52D68), 0.8 mm (A52D69), 1.1 mm (A52D70), 1.6 mm (A52D71), or IUCr standard pins for capillary stage (A52D72)
    • Storage magazine for goniometer heads (A52B38)
    • Storage magazine for capillaries mounted in capillary holders (A52B39)
    • Tungsten reference and verification sample 32 mm for Mo radiation (A52D133)

    Capillaries, capillary holders, capillary centering disks, polypropylene and Mylar foil are available as accessories or from the BRUKER web shop.